![Auerswald COMmander 6000 Advanced Information Download Page 422](http://html1.mh-extra.com/html/auerswald/commander-6000/commander-6000_advanced-information_3015895422.webp)
422
COMmander 6000/R/RX - Firmware V7.0D - Advanced Information V19 04/2018
Settings – Public switched tel. networks
Exchange line request
The PBX automatically distinguishes for each subscriber between
internal and external numbers by analysing the digit sequence and the
adjustment of the dialled phone number with the internal numbering plan.
The exchange line request type can be set separately for each
subscriber.
Important:
After a firmware update from an older firmware version to
version 6.6, the system-wide automatic exchange line request is at first
switched off. If the system-wide automatic exchange line request is
switched on, you must note the following for the conversion of the
existing phones:
COMfortel 600: For all phone numbers that are entered in the configu-
ration of the phone (concerns speed dialling keys and phone book),
possibly entered exchange line access numbers or ** (initiation of
internal numbers in the direct exchange line phone) must be deleted.
COMfortel 1100/1500/2500/2500 AB/2500 VoIP AB: For the call
forwarding variation „for external numbers“ the exchange line access-
number preceding the destination number must be deleted or omitted.
Exchange Line Access Number
Requirements:
•
Configured prefixes (country prefix and local area code)
•
Automatic exchange line request disabled