COMmander 6000/R/RX - Firmware V7.0D - Advanced Information V19 04/2018
1053
Appendix Hardware
Status Displays on the LEDs
Note:
If the
Power
LED remains constantly lit in red even after a restart,
an error has occured. Please contact your dealer or the manufacturer
directly.
Status LED:
Power LED:
PBX status (in the case of an error):
Flashes red (1/
1 s)
Lit in red
No valid boot partition was found.
System is paused.
Flashes orange
(1/1 s)
Lit in red
In both boot partitions no constant
kernel data were found. System is
paused.
Status LED:
Power LED:
PBX status (during powering down):
Lit in green
Flashes green
Indicates the period in which the
delayed powering down can be
initiated. If you let go of the button
during this period, the PBX powers
down after all current calls are termi-
nated.
Lit in green
Off
Indicates the period in which the PBX
can be powered down immediately. If
you let go of the button during this
period, the PBX powers down immedi-
ately and current calls will be inter-
rupted.
Lit in green
Flashes green
The delayed powering down has been
enabled and the PBX waits for the
termination of the last call.
Lit in green
Lit in red
The PBX is powered down completely.