![Altigen MAX Communication Server ACC 6.5 Administration Manual Download Page 145](http://html1.mh-extra.com/html/altigen/max-communication-server-acc-6-5/max-communication-server-acc-6-5_administration-manual_2911116145.webp)
Chapter 11: Board Configuration
MAXCS ACC 6.5 Administration Manual 131
T1/E1 Clocking
Depending on the configuration of the T1/E1 boards and span for your MAXCS
system(s), the
System Clock Master
setup should be set according to the follow
conditions:
•
If all of the T1/E1 boards are connected to a carrier’s switch, the
System Clock
Master
check box
must
not
be checked for
any
of the T1/E1 boards.
•
If two MAXCS systems are connected back-to-back with a T1/E1 span, the
System
Clock Master
check box
must be checked
for only
one
of the T1/E1 boards.
•
If two T1/E1 boards in the same MAXCS system are connected back-to-back with a
T1/E1 span, the
System Clock Master
check box
must be checked
for the T1/E1
board that has
not
been designated by the CT-Bus setting as the system’s master
clock to drive the CT-Bus.
Important:
For all back-to-back cases, the CT-Bus Clock Configuration should be set to
“Manual,” and the board that is connected to the board configured as the
back-to-back clock master
must
be designated at the CT-Bus master.
Setting up Channels on the Triton T1/E1 Board
This section discusses setting up T1 CAS, T1 PRI, E1 CAS, or E1 PRI channels on the
Triton T1/E1 board.
Click the
Protocol
button in the T1 or E1 configuration dialog box (see Figure 8 on
page 128) to open the
Protocol Configuration
window, shown below. The Triton T1/
E1 Board can be configured to either CAS or PRI through the configuration options in the
window.
The
CH -> Type
list on the left side of the window displays the channel types.
Note:
In a tie-trunk configuration, set the trunks to “Out of Service” before changing the
trunk type from T1 to PRI or vice versa. Otherwise, the system will generate
garbage call records to your internal or external logger service. See “Setting
General Trunk Attributes” on page 154 for details.
System Clock Master
You can set the
System Clock Master
if
you have a back-
to-back configuration and you want this span to be the
master clock to the system. (Only one clock master should
be selected in a back-to-back system.) See the following
section on T1/E1 clocking.
Option
Notes
Summary of Contents for MAX Communication Server ACC 6.5
Page 1: ...MAX Communication Server Administration Manual ACC 6 5 Update1 4 2010 4413 0001 6 5 Update1...
Page 14: ...xii MAXCS ACC 6 5 Administration Manual INDEX 467...
Page 16: ...2 MAXCS ACC 6 5 Administration Manual...
Page 36: ...Chapter 1 Overview 22 MAXCS ACC 6 5 Administration Manual...
Page 46: ...Chapter 2 System Requirements and Installation 32 MAXCS ACC 6 5 Administration Manual...
Page 88: ...Chapter 4 System Configuration 74 MAXCS ACC 6 5 Administration Manual...
Page 104: ...Chapter 6 Voice Mail Configuration 90 MAXCS ACC 6 5 Administration Manual...
Page 130: ...Chapter 9 Call Recording Configuration 116 MAXCS ACC 6 5 Administration Manual...
Page 134: ...Chapter 10 Application Extension Configuration 120 MAXCS ACC 6 5 Administration Manual...
Page 164: ...Chapter 11 Board Configuration 150 MAXCS ACC 6 5 Administration Manual...
Page 196: ...Chapter 13 In Call Routing Configuration 182 MAXCS ACC 6 5 Administration Manual...
Page 208: ...Chapter 14 Out Call Routing Configuration 194 MAXCS ACC 6 5 Administration Manual...
Page 240: ...Chapter 15 Extension Configuration 226 MAXCS ACC 6 5 Administration Manual...
Page 248: ...Chapter 16 Setting Up IP Extensions 234 MAXCS ACC 6 5 Administration Manual...
Page 262: ...Chapter 17 AltiGen IP Phone Configuration 248 MAXCS ACC 6 5 Administration Manual...
Page 272: ...Chapter 18 Mobile Extension Configuration 258 MAXCS ACC 6 5 Administration Manual...
Page 290: ...Chapter 20 Paging Group Configuration 276 MAXCS ACC 6 5 Administration Manual...
Page 318: ...Chapter 22 Workgroup Configuration 304 MAXCS ACC 6 5 Administration Manual...
Page 428: ...Chapter 29 TAPI Integration 414 MAXCS ACC 6 5 Administration Manual...
Page 474: ...460 MAXCS ACC 6 5 Administration Manual...