![Agilent Technologies 4294A Operating Manual Download Page 423](http://html.mh-extra.com/html/agilent-technologies/4294a/4294a_operating-manual_2867884423.webp)
Appendix B
415
Key Definitions
Softkeys displayed by pressing the [Local] key
B.
Ke
y De
fin
iti
on
s
Softkeys displayed by pressing the
[Local]
key
Table B-94
Local (Local) menu
Key operation:
[Local]
Softkey
Function
GPIB command
SYSTEM
CONTROLLER
|
Sets this instrument as the system controller when it is used in a GPIB system.
This mode can only be selected by manual operation with the SYSTEM
CONTROLLER key. Only one system controller can exist on each GPIB system.
Therefore, if there is already a system controller, you cannot set this instrument
as the system controller (“CAUTION: CAN'T CHANGE - ANOTHOR
CONTROLLER ON BUS” is displayed).
(N/A)
ADDRESSABLE ONLY
Sets this instrument in the addressable-only mode, in which an address can be
set, when it is used in a GPIB system. You select this mode when there is already
a system controller in the GPIB system. Also, when the controller passes the
authority for GPIB control to this instrument, this mode must be set.
(N/A)
ADDRESS: HP-IB
Sets the GPIB address used to control this instrument from an external controller.
(N/A)
ADDRESS:
CONTROLLER
Sets the address of this instrument as a controller. This address is used when a
controller passes the authority for GPIB control to this instrument.
ADDRCONT <value>
IP ADDRESS
ä
Displays Table B-95, “LAN address (LAN Address) menu,” on page 415.
See Table B-95
GATEWAY ADDRESS
ä
Displays Table B-95, “LAN address (LAN Address) menu,” on page 415.
See Table B-96
SUBNET MASK
ä
Displays Table B-95, “LAN address (LAN Address) menu,” on page 415.
See Table B-97
Table B-95
LAN address (LAN Address) menu
Key operation:
[Local] - IP ADDRESS
[Local] - GATEWAY ADDRESS
[Local] - SUBNET MASK
Softkey
Function
GPIB command
1st
Sets the 1st part of an IP address, gateway address, or subnet mask separated by
periods (.).
(Refer to corresponding
higher-level keys in
Table B-94, “Local
(Local) menu,” on page
415.)
2nd
Sets the 2nd part of an IP address, gateway address, or subnet mask separated by
periods (.).
3rd
Sets the 3rd part of an IP address, gateway address, or subnet mask separated by
periods (.).
4th
Sets the 4th part of an IP address, gateway address, or subnet mask separated by
periods (.).
done
Stores the configuration of the IP address, gateway address, or subnet mask
specified with the above keys and returns to Table B-94, “Local (Local) menu,”
on page 415. After performing the configuration, turn the Agilent 4294A off and
then on again so that the configuration takes effect.
(N/A)
Summary of Contents for 4294A
Page 1: ......
Page 2: ......
Page 4: ......
Page 5: ......
Page 6: ......
Page 8: ......
Page 16: ...8 ...
Page 30: ...22 Chapter1 Installation Power Cable Figure 1 2 Alternative Power Cable Options ...
Page 70: ...62 Chapter3 Front Rear Panel and LCD Display Items Displayed on the LCD ...
Page 436: ...428 AppendixB Key Definitions Softkeys displayed by pressing the Recall key ...
Page 454: ...446 AppendixC Error messages WRONG I O PORT DIRECTION ...