17-4
IM 701240-01E
Code
Message and Corrective Action
Section
753
Cannot start when the HISTORY menu is being displayed.
11.2
Press the ESC key to clear the menu before starting.
755
Time base cannot be set to external clock when set to envelope or box average.
5.20, 7.2
756
Cannot set accumulate during roll mode display. Turn Off accumulate.
5.2, 8.4
757
Cannot be executed when the acquisition mode is set to average. Change the mode.
7.2
758
Cannot copy if 50 pages is exceeded. Change the multiplier or range.
12.1
759
Realtime recording to the internal hard disk is valid when the record length is longer than 501 k.
5.2, 7.5
760
Cannot set the current drive on a realtime partition using communication commands.
7.5
761
Cannot be executed on realtime recorded waveforms.
7.5
764
File recorded in realtime is currently being analyzed. Files being analyzed cannot be deleted.
7.5, 13.16
765
File recorded in realtime is currently being analyzed.
7.5, 13.18
The name of files being analyzed cannot be changed.
766
File recorded in realtime is currently being analyzed.
7.5, 13.6
Partitions containing files that are being analyzed cannot be formatted.
767
128 and more file can’t be formed in the real-time area.
7.5
768
The file which failed in the real-time record can’t be read.
–
769
Cannot start Single(N) when accumulate is On. Change the accumulate to Off.
6.1, 8.4
773
The measuring range is up to 10 MWords from measure start (TimeRange1).
11.5
774
Synchronizing signal not detected.
6.17
775
Set acquisition mode to Normal when using a wave window trigger.
6.17
776
The wave window trigger cannot be used if the sampling rate is faster than 500 kS/s or slower
6.17
than 10 kS/s. If the record length is shorter than 25 k, set the record time longer than 100 ms.
777
Range over. Change to an appropriate range then retry shunt calibration.
5.15
778
Statistical processing cannot be performed on waveforms recorded in real time.
11.6
779
Cannot detect a effective input signal at a Sync. channel.
6.17
780
Firmware was not overwritten in the following slots, since the version of the firmware in the module
–
and that of the replacement firmware were the same. Check the versions on the overview screen.
SLOT: XX
781
Cannot start while the following setup menus are displayed. Press the ESC key to clear
–
the menu, and then start.
(ALL CH, ZOOM, MEASURE, CURSOR, and PrintSetup)
782
Firmware was not overwritten, since the version of the firmware in the printer and that
17.4
of the replacement firmware were the same.
783
Checksum error in the printer control program.
3.4
Recycle the power. If the error occurs again, maintenance service is required.
784
Failed to transmit the printer control program.
3.4
Recycle the power. If the error occurs again, maintenance service is required.
785
Failed to write the printer control program.
3.4
Recycle the power. If the error occurs again, maintenance service is required.
787
Cannot be carried out during recording.
7.1
Press the START/STOP key to stop the waveform acquisition first.
788
Cannot start while the alert dialog box is open.
–
Press the ESC key to clear the dialog box, and then start.
789
Cannot copy if 100 pages is exceeded.
9.7, 12.1
Change the multiplier or range.
790
Fine Print or Zoom Print is not possible when X-Y display is present.
8.6, 12.1
791
Up to 30 items can be registered.
4.2
792
Not entered in “Yomi” or “Goku.”
4.2
793
Cannot specify characters other than “Hiragana” for “Yomi.”
4.2
794
Kanji registration error. Below are the possible causes.
4.2
• More than 17 items are registered with the same “Yomi.”
• Exceeded the dictionary registration capacity.
17.2 Messages and Corrective Actions