11-7
IM 701240-01E
Waveform Analysis/Search
3
2
1
4
5
6
7
8
9
10
11
11
12
13
14
15
16
17
18
App
Index
Explanation
You can search for a waveform that matches the specified conditions from the past
waveforms in the acquisition memory and display it.
Select Zone
Four types of search zones can be registered in Zone1 to Zone4. You can set the
channel that is to be searched, the search condition, and the search range for each
search zone.
Condition
IN:
Searches for waveforms that pass through the specified search window.
OUT:
Searches for waveforms that do not pass through the specified window.
OFF:
Does not search for waveforms.
Source
Search is carried out on the channel that is specified as the Source. The channels that
can be specified are CH1 to CH16. Waveforms of other channels are also displayed.
Vertical Range of Search Window (Upper/Lower)
The selectable range is
±
5 divisions. The resolution is 0.01 divisions.
Upper must always be greater than or equal to Lower.
Horizontal Range of Search Window (Left/Right)
The selectable range is
±
5 divisions. The resolution is (10 division/record length).
Right must always be greater than or equal to Left.
Logic
AND: Searches for waveforms that meet all search conditions from Zone1 to Zone4.
OR:
Searches for waveforms that meet any one of the search conditions from Zone1
to Zone4.
Search Range
The search range is between the Start Record and the End Record.
Search Order
The search is carried out from the most recent waveform to the oldest waveform.
Show Map (A List of Time Stamps)
Only the waveforms that are found are listed in Show Map. If the Search Mode is turned
OFF, all waveforms from Start Record to End Record are displayed.
11.2 Searching History Memory Data Using Zones (History Search Function)