Horizontal and Vertical Axes
Voltage Range (When Variable Is ON)
When Variable is ON, you can adjust the displayed amplitude of the waveform by
changing the Upper and Lower values. For the operating procedure, see section 5.9.
Even if you change the range using the RANGE knob when Variable is ON, the new
range is not applied to the waveform amplitude. This is because the Upper and Lower
values are not changed. The new range takes effect when Variable is turned OFF.
Note
If you turn the jog shuttle while waveform acquisition is stopped and change the Upper and
Lower values, the displayed waveforms also change.
Display Position of Range
If you turn the RANGE knob while waveform acquisition is stopped, the top row of the
range display shows the span (range that can be displayed between the top and
bottom edges of the waveform display area (10 divisions), see section 5.9) for the
displayed waveform, and the bottom row shows the new range. The new range takes
effect the next time acquisition is started.
Top row:
Span corresponding to the displayed waveform*
Bottom row: Changed range*
* If you change the range while waveform acquisition is stopped, the
range value in the bottom row is shown in parentheses. The span
value in the top row does not change.
5.3 Setting the Voltage Range