NOTICE: Use the hanging brackets on the top and hanging holes of the bottom cover when lifting drive models 2
o
0154F, 2
o
0192F,
4
o
0156F, and 4
o
0180F.
2
□
0154F, 2
□
0192F, 4
□
0156F, and 4
□
0180F
2
□
0154A, 2
□
0192A, 2
□
0248,
4
□
0156A, 4
□
0180A, and 4
□
0216 to 4
□
0414
Figure 2.4 Horizontal Suspension of Drive Model 2
o
0154
n
Vertical Suspension of the Drive
Follow the procedure described below when suspending the drive with eye bolts or hanging brackets.
Drive Models 2
o
0028 to 2
o
0130 and 4
o
0011 to 4
o
0124
WARNING! Crush Hazard. Use an adequate length of wire to ensure a 50° or wider suspension angle as illustrated in
maximum allowable load of the eye bolts cannot be guaranteed when the drive or harmonic filter module is suspended with the wires at
angles less than 50°. Failure to comply may result in serious injury or death from falling equipment.
1.
Pass wire through the holes of the two eye bolts.
Suspending angle:
50° or greater
Figure 2.5 Suspension Using Wires and Eye Bolts
2.
Gradually take up the slack in the wires and hoist the drive or harmonic filter module after the wires are stretched tight.
3.
Lower the drive when ready to install in the enclosure panel. Stop lowering when near the floor, then slowly begin lowering
the drive or again until the drive is placed correctly.
2.2 Mechanical Installation
40
YASKAWA TOEPYAIUPW01A YASKAWA AC Drive - U1000 iQpump Matrix Drive User Manual