No.
(Addr.
Hex)
Name
LCD Display
Description
Values
Page
F6-53
(03C4) DeviceNet PPA Setting PPA Selection
Sets the format of the data set from the drive to the DeviceNet
master.
Default: 71
Min.: 0
Max.: 255
–
F6-54
(03C5)
DeviceNet Idle Mode
Fault Detection
DN Idle Flt Det
0: Stop
1: Ignore
0: Enabled
1: Disabled, no fault detection
Default: 0
Range: 0, 1
–
F6-55
(03C6)
DeviceNet Baud Rate
Monitor
DN BAUD RATE
MEM
0: 125 kbps
1: 250 kbps
2: 500 kbps
Verifies the baud rate running on the network.
0: 125 kbps
1: 250 kbps
2: 500 kbps
Default: 0
Range: 0 to 2
–
F6-56
(03D7)
DeviceNet Speed
Scaling
Speed Scale
Sets the scaling factor for the speed monitor in DeviceNet.
Default: 0
Min.: -15
Max.: 15
–
F6-57
(03D8)
DeviceNet Current
Scaling
Current Scale
Sets the scaling factor for the output current monitor in
DeviceNet.
Default: 0
Min.: -15
Max.: 15
–
F6-58
(03D9)
DeviceNet Torque
Scaling
Torque Scale
Sets the scaling factor for the torque monitor in DeviceNet.
Default: 0
Min.: -15
Max.: 15
–
F6-59
(03DA)
DeviceNet Power
Scaling
Power Scale
Sets the scaling factor for the power monitor in DeviceNet.
Default: 0
Min.: -15
Max.: 15
–
F6-60
(03DB)
DeviceNet Voltage
Scaling
Voltage Scale
Sets the scaling factor for the voltage monitor in DeviceNet. Default: 0
Min.: -15
Max.: 15
–
F6-61
(03DC) DeviceNet Time Scaling Time Scale
Sets the scaling factor for the time monitor in DeviceNet.
Default: 0
Min.: -15
Max.: 15
–
F6-62
(03DD)
DeviceNet Heartbeat
Interval
DN Heart Beat
Sets the heartbeat interval for DeviceNet communications.
Default: 0
Min.: 0
Max.: 10
–
F6-63
(03DE)
DeviceNet Network
MAC ID
DN MAC ID MEM
Saves and monitors settings 0 to 63 of F6-50 (DeviceNet MAC
Address).
Default: 63
Min.: 0
Max.: 63
–
F6-64 to
F6-71
(03DF to
03C8)
Reserved
–
Reserved for Dynamic I/O Assembly Parameters.
–
–
<1> Parameter setting value is not reset to the default value when the drive is initialized.