U1-76
(0852) Date – Year
Date Year
Displays the current year.
No signal output
available
–
U1-77
(0853) Date – Month/Day
Date Mo Day MMDD Displays the current date (Month and Date).
No signal output
available
–
U1-78
(0854) Date – Week Day
Date Week
Displays the current day of the week.
0: Sunday
1: Monday
2: Tuesday
3: Wednesday
4: Thursday
5: Friday
6: Saturday
No signal output
available
–
U1-79
(0B9A) PI Feedback Back-up
PI Fdbk Backup
Displays the PI Feedback Back-up signal (H3-
oo
= 24) used
when the primary PI Feedback (H3-
oo
= B) is lost.
No signal output
available
Dep. on
P1-02
U1-81
(0B9C) Differential PI Feedback Diff PI Feedback
Differential Feedback signal (H3-
oo
= 28).
No signal output
available
Dep. on
P1-02
U1-82
(0B9D)
Two Motor Time to
Alternate
2Motor Alt Time
Time remaining before making a motor switch.
No signal output
available
min
U1-83
(0B9E) Flow Rate
Flow Rate
Displays the flow rate based on the pulse input frequency or the
analog voltage (flow rate input) and parameters P6-01 and P6-04.
A 2-second first order filter will be applied to this monitor.
Full scale:
P6-01
Dep. on
P6-04
and
P6-22
U1-84
(0B9F)
Accumulation Level -
Millions
Volume * 1000000
Displays the recorded volume from the flow meter (pulse input
or analog voltage).
Total volume is calculated as follows:
Total Volume = (U1-84 * 1000000) + (U1-85 * 1000) + U1-86
+ U1-87
No signal output
available
Dep. on
P6-16
U1-85
(0BA0)
Accumulation Level -
Thousands
Volume * 1000
U1-86
(0BA1)
Accumulation Level -
Ones
Volume * 1
U1-87
(0BA2)
Accumulation Level -
Decimal
Volume * 0.0001
U1-88
(N/A)
Total Volume
Accumulated
Total Vol (gal) or
Total Vol (A-F)
Displays the total volume.
Full scale: N/A Dep. on
P6-16
U1-89
(N/A)
Delta Volume
Accumulated
Delta Vol (gal) or
Total Vol (A-F)
Displays the delta volume: Total Volume (U1-88/U1-84 to
U1-87) - Starting Delta Volume (P6-36 to P6-39).
Full scale: N/A Dep. on
P6-16
U1-90
(0BA5) Pump Setpoint
Pump Setpoint
Displays the PID Setpoint.
No signal output
available
Dep. on
P1-02
U1-91
(0BA6)
Pump Feedback
Pump Feedback
Displays the PID Feedback.
No signal output
available
Dep. on
P1-02
U1-92
(0BA7) Pump Status
Pump Status
Displays Pump Running Status.
U1 - 92=
00000000
Drive
Pump 2
Pump 3
Pump 4
Pump 5
Pump 6
Not used
Not used
1
1
1
1
1
1
0
0
No signal output
available
–
U1-93
(0BA8)
Total Setpoint
Compensation
Total SP Comp.
Displays the total absolute Setpoint Compensation.
No signal output
available
Dep. on
P1-02
U1-94
(0BA9) Motor Speed
Motor Speed
Displays the absolute value of the output frequency (U1-02)
converted to RPM.
No signal output
available
1 RPM
B.16 U: Monitors
YASKAWA TOEPYAIUPW01A YASKAWA AC Drive - U1000 iQpump Matrix Drive User Manual
355
B
Parameter List