Using the Digital Operator
7.2.9 Initializing User Constant Settings
7 -40
Using the Panel Operator
1.
Press the MODE/SET Key to select the auxiliary function mode.
2.
Press the Up or Down Cursor Key to select the user constant Fn005.
3.
Press the DATA/SHIFT Key for a minimum of one second, and the display will be as shown
below.
4.
Press the MODE/SET Key, and the display will be as shown below. The user constants will
be initialized.
Flashing for
one second
Flashing during
initialization
End
5.
Press the DATA/SHIFT Key for a minimum of one second to return to the auxiliary function
mode display.
This completes the initialization of user constant settings.
User constants will not be initialized by pressing the DSPL/SET or MODE/SET Key with the servo ON. Turn
the power OFF and then back ON after initialization.