Host Controller Connection Examples
A -8
A.7 Connecting MITSUBISHI’s AD75 Positioning Unit
The following diagram shows an example of connecting to the MITSUBISHI AD75 Positioning
Unit. In this example, the Servopack is used in Position Control Mode.
+
--
+24v
0
24
V
1Ry
CN1
CN1
AD75
(Made by Mitsubishi)
STOP
DOG
READY
PGO
PULSE
SIGN
CLEAR
1Ry
*
2.2K
W
19
14
15
12
11
8
7
32
31
20
42
43
40
47
/S-ON
P-OT
N-OT
25
24
11
14
7
26
23
5
22
4
21
3
+24 V
ON when
proximity is
detected.
ON when
positioning is
canceled.
CN2
I/O Power Supply
X axis
(Y axis)
L1C
L3
L2
L1
L2C
Servomotor
M
PG
Servopack
W
V
A (1)
B (2)
C (3)
D (4)
U
SGDH
0
24
V
+24 V
PULSE
CLR
SIGN
/PULSE
/CLR
/SIGN
ALM+
ALM--
PCO
/PCO
* The ALM signal is output for approximately two seconds when the power is turned ON. Take this into consider-
ation when designing the power ON sequence. The ALM signal actuates the alarm detection relay 1Ry to stop
main circuit power supply to Servopack.
Note
Only signals applicable to MITSUBISHI’s AD75 Positioning Unit and Yaskawa’s SGDH Servopack are
shown here.