User Constant Settings and Functions
5.3.5 Control Mode Selection
5 -58
5.3.5 Control Mode Selection
The SGDH Servopack offers speed control, position control, torque control, and the other con-
trol modes shown in the following table.
The following user constant is used to set the control mode.
Pn000.1
Control Mode Selection
Factory
Setting:
0
Speed/Torque
Control,
Position Control
Pn000.1 Setting
Control Mode
0
Speed Control (Analog Reference)
1
Position Control (Pulse Train Reference)
2
Torque Control (Analog Reference)
3
Contact Input Speed Control Selection (Contact Reference)
4
Contact Input Speed Control Selection (Contact Reference)
«
Speed Con-
trol (Analog Reference)
5
Contact Input Speed Control Selection (Contact Reference)
«
Position
Control (Pulse Train Reference)
6
Contact Input Speed Control Selection (Contact Reference)
«
Torque
Control (Analog Reference)
7
Position Control (Pulse Train Reference)
«
Speed Control (Analog Refer-
ence)
8
Position Control (Pulse Train Reference)
«
Torque Control (Analog Ref-
erence)
9
Torque Control (Analog Reference)
«
Speed Control (Analog Reference)
A
Speed Control (Analog Reference)
«
Zero Clamp Control
B
Position Control (Pulse Train Reference)
«
Position Control (Inhibit)
J
J
Description of Control Modes
The control modes are described below.
Speed Control (Analog Reference)
This mode controls speed using an analog voltage input reference. See
5.2.1 Speed Reference
.
Position Control (Pulse Train Reference)
Thismode controlspositioning using a pulse train input reference. See
5.2.2 Position Reference.
Torque Control (Analog Reference)
Thismode controls torque using an analog voltage input reference. See
5.2.7 Using Torque Con-
trol.
Contact Input Speed Control Selection (Contact Reference)
This mode uses the /P-CON (/SPD-D), /P-CL (/SPD-A), and /N-CL (/SPD-B) input signals to
control speed as it switches among the three preset operating speeds in the Servopack. See
5.2.6
Contact Input Speed Control.
5