User Constant Settings and Functions
5.2.7 Using Torque Control
5 -36
5.2.7 Using Torque Control
The SGDM Servopack limits torque as shown below.
D
Level 1: Limits maximum output torque to protect the equipment or workpiece.
D
Level 2: Limits torque after the Servomotor movesthe equipment to a specified position (in-
ternal torque limit).
D
Level 3: Always control torque rather than speed output.
D
Level 4: Switches between speed and torque control.
The following describes uses for levels 3 and 4 in the torque control function.
J
J
Torque Control Selection
Set in the following user constants to select level 3 or 4 torque control.
Pn000.1
Control Method Selection
Factory
Setting:
0
Speed/Torque
Control,
Position Control
A torque reference is input from the host controller to the Servopack in order to control torque.
5