7.1 Basic Operation
7 -17
Output Signal Monitor Display
4 3 2 1
Top: OFF (“H” level)
Bottom: ON (“L” level)
Number
7 6 5
LED Number
Output Terminal Name
Factory Setting
1
(CN1-31, -32)
ALM
2
SO1 (CN1-25, -26)
/COIN or /V-CMP
3
SO2 (CN1-27, -28)
/TGON
4
SO3 (CN1-29, -30)
/S-RDY
5
(CN1-37)
AL01
6
(CN1-38)
AL02
7
(CN1-39)
AL03
Note
Refer to
5.3.4 Output Circuit Signal Allocation
for details on output terminals.
Output signalsare allocated asshown above and displayed on the panel display of the Servopack
or the Digital Operator. They are indicated by ON/OFF display of seven-segment LEDs in top
and bottom rows. These segments turn ON depending on the output signals (ON for “L” level
and OFF for “H” level).
D
When ALM signal operates (alarm at “H”)
The top segment of
number 1 is lit.
4 3 2 1
7 6 5
7
A
EXAMPLE
"