Using the Digital Operator
7.2.10 Manual Zero Adjustment and Gain Adjustment of Analog Monitor Output
7 -44
J
J
Manual Gain Adjustment of Analog Monitor Output
Follow the procedure below to execute the manual gain adjustment of analog monitor output.
Using the Hand-held Digital Operator
1.
Press the DSPL/SET Key to select the auxiliary function mode.
2.
Select the user constant Fn00D.
Press the Left or Right Cursor Key to select the digit.
Press the Up or Down Cursor Key to change the value.
3.
Press the DATA/ENTER Key, and the display will be as shown below.
4.
Press the DSPL/SET Key, and the monitor output for the two channels will be displayed al-
ternately as shown below.
DSPL/SET Key
Displayed
Alternately
5.
Press the Left or Right Cursor Key to display the analog monitor gain constant. Pressing the
Left or Right Cursor Key again will return to the display shown in the above step 3. or 4.
Left Cursor Key
(Right Cursor Key)
Data Display
Displayed
Alternately
6.
Press the Up or Down Cursor Key to adjust the gain for the analog monitor output.
Data Setting Change
7.
When the gain adjustment has been completed for the two channels, press the DATA/EN-
TER Key to return to the auxiliary function mode display.
This completes the manual gain adjustment of the analog monitor output.