Servo Adjustment
6.3.4 User Constants Related to Online Autotuning
6 -24
J
J
Friction Compensation Selection
Use the following user constant to enable or disable friction compensation to determine whether
or not the friction of the servo system is to be taken into consideration for the calculation of load
inertia.
If this compensation function is enabled, select small or large friction compensation according
to the extent of friction in order to ensure highly precise load inertia calculation.
Pn110.2
Friction Compensation Selection
Factory
Setting:
1
Speed Control,
Position Control
Pn110.2 Setting
Description
0
Friction compensation: Disabled
1
Friction compensation: Small
2
Friction compensation: Large
1.
Do not set friction compensation for loads with low friction (10% rated torque/speed or less).
2.
Autotuning will be perform as if the load inertia was 30 times the motor inertia.