5.1 Settings According to Device Characteristics
5 -7
Pn001.1
Overtravel Stop Mode
Factory
Setting:
0
Speed/Torque
Control,
Position Control
Stop by dynamic
brake
Coast to a stop
Decelerate to a
stop
Zero clamp
Coast status
Coast
status
Pn001.1
setting
Stop Mode
After stopping
Pn001.1 = 1 or 2
Pn001.0 = 0, 1
Pn001.1 = 0
0
1
2
2
Overtravel
For torque control, the servomotor will be placed in coast status after either decelerating or coasting to a stop
(according to the stop mode set in Pn001.0), regardless of the setting of Pn001.1.
User Constant
Setting
Item
Pn001.1
0
Stops the Servomotor the same way as turning the
servo OFF (according to Pn001.0).
1
Decelerates the Servomotor to a stop at the preset
torque, and then locks the Servomotor in Zero Clamp
Mode.
Torque setting: Pn406 emergency stop torque
2
Decelerates the Servomotor to a stop at the preset
torque, and puts the Servomotor in coast status.
Torque setting: Pn406 emergency stop torque
Pn406 specifies the stop torque applied for overtravel when the input signal for prohibiting for-
ward or reverse rotation is used.
The torque limit is specified as a percentage of rated torque.
Pn406
Emergency Stop
Torque
Unit:
%
Setting
Range:
0 to Max.
Torque
Factory
Setting:
800
Valid when
Pn001.1 is 1 or 2
Max. torque setting for an
emergency stop
Forward run
prohibit input
P-OT (CN1-42)
Reverse run
prohibit input
N-OT (CN1-43)
Stop Mode
Pn406
Stop by dynamic brake
Coast to a stop
Decelerate to a stop
5
INFO
AUDIN - 7 bis rue de Tinqueux - 51100 Reims - France - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : [email protected]