8.2 Servopacks
8 -33
8.2.2 Ratings and Specifications
The following table shows ratings and specifications for the SGDH Servopack. Refer to them
as required when selecting a Servopack.
Table 8.14 Servopack Ratings and Specifications
Servopack Model
SGDH-
A3
A5
01
02
04
05
08
10
15
20
30
Appli-
cable
100V
SGMAH-
j
B
A3
A5
01
02
--
--
--
--
--
--
--
Appli-
cable
Servo-
100V
SGMPH-
j
B
--
--
01
02
--
--
--
--
--
--
--
Servo-
motor
200V
SGMAH-
j
A
A3
A5
01
02
04
--
08
--
--
--
--
motor
200V
SGMPH-
j
A
--
--
01
02
04
--
08
--
15
--
--
SGMGH-
j
A
j
A (1500r/min)
--
--
--
--
--
05
--
09
13
20
30
SGMGH-
j
A
j
B (1000r/min)
--
--
--
--
--
03
06
09
12
20
30
SGMSH-
j
A
--
--
--
--
--
--
--
10
15
20
30
SGMDH-
j
A
--
--
--
--
--
--
--
--
--
--
22
400V
SGMGH-
j
D
--
--
--
--
--
05
--
09
13
20
30
400V
SGMSH-
j
D
--
--
--
--
--
--
--
10
15
20
30
SGMUH-
j
D
--
--
--
--
--
--
--
10
15
--
30
Basic
Specifi-
cations
Max. Applicable Servomotor Capacity
[kW]
0.03 0.05 0.1
0.2
0.4 0.45 0.75 1.0
1.5
2.0
3.0
Specifi-
cations
100V
Continuous Output Current [A
rms]
0.66 0.95 2.4
3.0
--
--
--
--
--
--
--
Max. Output Current [A rms]
2.0
2.9
7.2
9.0
--
--
--
--
--
--
--
200V
Continuous Output Current [A
rms]
0.44 0.64 0.91 2.1
2.8
3.8
5.7
7.6 11.6 18.5 24.8
Max. Output Current [A rms]
1.3
2.0
2.8
6.5
8.5 11.0 13.9
17
28
42
56
400V
Continuous Output Current [A
rms]
--
--
--
--
--
1.9
--
3.5
5.4
8.4 11.9
Max. Output Current [A rms]
--
--
--
--
--
5.5
--
8.5
14
20
28
Input
Power
Main circuit
100 V
Single-phase 100 to 115 VAC +10 to --15%, 50/60 Hz
Input
Power
Supply
Main circuit
200 V
Single/Three-phase 200 to 230 VAC +10 to --15%, 50/60 Hz*
6
Supply
*
1
400 V
Three-phase 380 to 480 VAC +10 to --15%, 50/60 Hz
*
1
Control circuit
100 V
Single-phase 100 to 115 VAC +10 to --15%, 50/60 Hz
Control circuit
200 V
Single-phase 200 to 230 VAC +10 to --15%, 50/60 Hz
400 V
24 VDC 15%
Control Method
Single or three-phase full-wave rectification IGBT-PWM (sine-wave
driven)
Feedback
Serial encoder: 13, 16 or 17-bit (incremental/absolute value)
* The 13 bit encoder is incremental only.
Condi-
tions
Ambient/Storage Temperature
*2
0 to +55
°
C/--20 to +85
°
C
tions
Ambient/Storage Humidity
90% RH or less (with no condensation)
Vibration/Shock Resistance
4.9 m/s
2
/19.6 m/s
2
Configuration
Base mounted (Can be rack mounted with optional specifications.)
8