User Constant Settings and Functions
5.5.5 Using the Running Output Signal
5 -74
5.5.5 Using the Running Output Signal
The basic use and wiring procedures for the running (/TGON) output signal (photocoupler out-
put signal) are described below. The signal is output to indicate that the Servomotor is currently
operating.
CN1-27
CN1-28
/TGON+
/TGON--
+24 V
0 V
Photocoupler output
(per output)
Maximum operating voltage:
30 VDC
Maximum output current: 50 mA
DC
Servopack
I/O power supply
Output
®
/TGON CN1-27
Running Output Signal
Speed/Torque
Control,
Position Control
This signal is output to indicate that the Servomotor is currently operating. It is used as an exter-
nal interlock.
ON:
Closed or low level
Servomotor is operating. (Motor speed is
above the setting.)
OFF:
Open or high level
Servomotor is not operating. (Motor speed is
below the setting.)
Preset value: Pn502 (Running Output Level)
Motor speed
(Un000)
/TGON
Pn502
The following user constant setting is used to change the CN1 connector terminal that outputs
the /TGON signal.
Pn50E
Output Signal Selections 1
Factory
Setting:
3211
Speed/Torque
Control,
Position Control
The user constant isfactory set so the /V-CMPsignal isoutput between CN1-27 and 28. See
5.3.4
Output Circuit Signal Allocation
for more details on user constant Pn50E.
This user constant is used to set output conditions for the operation detection output signal /
TGON.
Pn502
Rotation Detection
Level
Unit:
r/min
Setting
Range:
1 to 10000
Factory
Setting:
20
Speed/Torque
Control,
Position Control
This user constant is used to set the speed at which the Servopack determines Servomotor opera-
tion and outputs a signal. The following signals are output when motor speed exceeds the preset