![YASKAWA E-II SGM H Series Скачать руководство пользователя страница 86](http://html1.mh-extra.com/html/yaskawa/e-ii-sgm-h-series/e-ii-sgm-h-series_user-manual_3266058086.webp)
4.2 Supplementary Information on Trial Operation
4 -11
4.2.2 Position Control by Host Controller
If position control from the host controller has not been confirmed, disconnect the Servomotor
from the equipment and perform a trial operation, otherwise the Servomotor may run out of con-
trol. Check Servomotor operation as described in the following table.
Trial operation for
Servomotor without load
M
Host
controller
Position control
Speed control
Reference
speed
SGDH
Servopack
Reference from
the Host
Controller
Check Item
Check Method
Review Items
JOG Operation
(Constant
Reference
Speed Input
from Host
Controller)
Motor speed
Check motor speed as fol-
lows:
S
Use the speed monitor
(Un000) on the Panel Op-
erator.
S
Run the Servomotor at low
speed. Input a reference
speed of 60 r/min for ex-
ample to check to see if
the Servomotor makes one
revolution per second.
Check the user constant set-
ting at Pn300 to see if refer-
ence speed gain is correct.
Simple
Positioning
No. of motor
rotations
Input a reference equivalent
to one Servomotor rotation
and visually check to see if
the shaft makes one revolu-
tion.
Check the user constant set-
ting at Pn201 to see if the
number of dividing pulses is
correct.
Overtravel
(P-OT and
N-OT Used)
Whether the
Servomotor
stops rotating
when P-OT and
N-OT signals
are input
Check to see if the Servomo-
tor stops when P-OT and
N-OT signals are input during
continuous Servomotor op-
eration.
Review P-OT and N-OT wir-
ing if the Servomotor does
not stop.
4
AUDIN - 7 bis rue de Tinqueux - 51100 Reims - France - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : [email protected]