5.1 Settings According to Device Characteristics
5 -11
Note
Multiple signals allocated to the same output circuit are output using OR logic.
Set other output signals to a value other than that allocated to the /CLT signal
in order to use just the /CLT output signal. See
5.3.4 Output Circuit Signal Al-
location.
J
J
Setting Level 2: External Torque Limit
Acontactinputsignalisusedtoenablethe torque(current) limitspreviously setin userconstants.
Torque limits can be set separately for forward and reverse rotation.
Torque
Torque limit
Pn402 or Pn404
(limited by whichever
is smaller)
Servopack
Forward
rotation
Reverse
rotation
/P-CL
CN1-45
Torque limit
Pn403 or Pn405
(limited by whichever is
the smaller)
Torque limit
Pn402
Torque limit
Pn403
Rotation
speed
Torque
Torque
Torque
Rotation
speed
Rotation
speed
Rotation
speed
/N-CL
CN1-46
®
Input /P-CL CN1-45
Forward External Torque Limit
Input
Speed/Torque
Control,
Position Control
®
Output /N-CL CN1-46
Reverse External Torque Limit
Input
Speed/Torque
Control,
Position Control
This is the external torque (current) limit input for forward and reverse rotation.
Checkinput signalallocation statuswhen usingthisfunction.(See
5.3.3Input CircuitSignal
Allocation.
) Factory settings are given in the following table.
/P-CL
CN1-45 at low level
when ON
Use forward torque limit.
Limit:
Pn404
CN1-45 at high level
when OFF
Do not use forward torque limit.
Normal operation.
--
/N-CL
CN1-46 at low level
when ON
Use reverse torque limit.
Limit:
Pn405
CN1-46 at high level
when OFF
Do not use reverse torque limit. Normal operation.
--