User Constant Settings and Functions
5.1.2 Setting the Overtravel Limit Function
5 -8
J
J
Servo OFF Stop Mode Selection
The SGDH Servopack turns OFF under the following conditions:
D
Servo ON input signal (/S-ON, CN1-40) is turned OFF.
D
Servo alarm occurs.
D
Power is turned OFF.
Specify the Stop Mode if any of these occurs during operation.
Pn001.0
Servo OFF or Alarm Stop Mode
Factory
Setting:
0
--
Stop Mode
After stopping
Hold with
dynamic brake
0
1
Pn001.0 = 0
or 1
Servo
OFF
Pn001.0 = 2
The dynamic brake electrically applies a
brake by using a resistor to consume
Servomotor rotation energy.
See
5.4.2 Using the Dynamic Brake.
Stop by dynamic
brake
Coast to a stop
Coast status
Coast status
User Constant
Setting
Item
Pn001.0
0
(Factory setting)
Uses the dynamic brake to stop the Servomotor, and
maintains dynamic brake status after stopping.
1
Uses the dynamic brake to stop the Servomotor, and
cancels dynamic brake status after stopping to go into
coast status.
2
Coasts the Servomotor to a stop. The Servomotor is
turned OFF and stops due to equipment friction.
Note
If the Servomotor is stopped or rotating at extremely low speed when the items
above are set at 0 (dynamic brake status after stopping with the dynamic brake),
then braking power is not generated and the Servomotor will stop the same as
in coast status.