Servo Adjustment
6.3.3 Saving Results of Online Autotuning
6 -22
3.
Press the DSPL/SET Key. The following display will flash for 1 second and then the inertia
ratio will be saved.
Flashes for
1 s.
4.
Press the DATA/ENTER Key to return to the auxiliary function mode.
This completes the procedure for saving the results of online autotuning. When the Servopack
is turned on again, the inertia ratio set in Pn103 will be used as the default value.
Using the Built-in Panel Operator
1.
Press the MODE/SET Key and select Fn007 in the auxiliary function mode.
2.
Press the DATA/SHIFT Key for a minimum of 1 second. If the inertia ratio is 200%, for ex-
ample, the following data will be displayed.
3.
Pressthe MODE/SET Key. The following display will flash for 1 second and then the inertia
ratio will be saved.
Flashes for
1 s.
4.
Press the DATA/SHIFT Key for a minimum of 1 second to return to the auxiliary function
mode.
This completes the procedure for saving the results of online autotuning. When the Servopack
is turned on again, the inertia ratio set in Pn103 will be used as the default value.
6