7.2 Applied Operation
7 -31
7.2.5 Clearing Alarm Traceback Data
This procedure clears the alarm history, which stores the alarms generated in the Servopack.
Each alarm in the alarm history is set to A.-- --, which is not an alarm code. Refer to
Section 7.2.1
Operation in Alarm Traceback Mode
for details.
Follow the procedure below to clear the alarm traceback data.
Using the Hand-held Digital Operator
1.
Press the DSPL/SET Key to select the auxiliary function mode.
2.
Select the user constant Fn006.
Press the Left or Right Cursor Key to select the digit.
Press the Up or Down Cursor Key to change the value.
3.
Press the DATA/ENTER Key, and the display will be as shown below.
4.
Press the DSPL/SET Key to clear the alarm traceback data. The following display will flash
for one second, and, after the alarm traceback data is cleared, the display will return to the
one in the above step 3.
Flashing for
one second
5.
Presss the DATA/ENTER Key to return to the user constant code display.
This completes the alarm traceback data clearing procedure.