7.2 Applied Operation
7 -49
Using the Panel Operator
1.
Press the MODE/SET Key to select the auxiliary function mode.
2.
Press the Up or Down Cursor Key to select the user constant Fn00F.
3.
Press the DATA/SHIFT Key for a minimum of one second, and the display will be as shown
below.
4.
Press the MODE/SET Key to switch between U-phase (Cu1_0) and V-phase (Cu2_0) cur-
rent detection offset adjustment mode.
MODE/SET Key
Displayed
Alternately
5.
Press the DATA/SHIFT Key for less than one second to display the current detection data.
Press the DATA/SHIFT Key again for less than one second, and the display will return to
one shown in the above step 3. or 4.
Data Display
DATA/SHIFT Key
Displayed
Alternately
6.
Pressthe Up or Down Cursor Key to adjust the offset. Carefully adjust the offset while moni-
toring the torque reference monitor signal.
Data Setting Change
7.
When the current offset adjustment has been completed for the U-phase (Cu1_0) and V-
phase (Cu2_0), pressthe DATA/SHIFT Key to return tothe auxiliaryfunction modedisplay.
This completes the manual adjustment of the motor current detection offset.