![YASKAWA E-II SGM H Series Скачать руководство пользователя страница 40](http://html1.mh-extra.com/html/yaskawa/e-ii-sgm-h-series/e-ii-sgm-h-series_user-manual_3266058040.webp)
3.1 Connecting to Peripheral Devices
3 -5
3.1.2 Three-phase (200 V) Main Circuit Specifications
L1
L2
L3
U
V
W
L1C
L2C
B1
B2
B3
1
2
C
N
3
C
N
1
C
N
2
MODE/SET
DATA/
CHARGE
POWER
Power supply
Three-phase 200 VAC
L1 L2 L3L1C L2C
B1 B2
U V W
If the capacity of the internal regenerative resistor is
insufficient, remove the wire between B2 and B3 and
connect an external regenerative resistor to terminals
B1 and B2.
For Servopacks with a capacity of 6.0 kW or higher,
connect an external regenerative resistor between
terminals B1 and B2 (There is no terminal B3 on
these Servopacks.)
YASKAWA
SERVOPACK
SGDH-
200V
MEMOCON GL120, GL130,
MP920 with a motion module
Host
Controller
Connect the SGDH Servopack to a Yas-
kawa host controller or one made by
another company.
Digital Operator
Personal Computer
Cable model: JZSP-CMS01 to 03
Molded-case Circuit
Breaker
(QF)
Protects the
power line by
shutting the circuit
OFF when over-
current is de-
tected.
Noise Filter
Used to eliminate external noise
from the power line.
Magnetic Contactor
Molded-case
circuit breaker
Noise filter
Regenerative Resistor
Regenerative
resistor
(optional)
Brake Power Supply
Used for a Servomotor with a
brake.
Encoder
Cable
Encoder
Connector
Brake
power
supply
Magnetic
contactor
Magnetic
contactor
Power
supply
ground
line
HI Series
Turns the servo
ON and OFF.
Install a surge
suppressor on the
magnetic contac-
tor.
JUSP-OP02A-2
Allows the user to set
user constants or op-
eration references and
to display operation or
alarm status.
Communication is also
possible with a per-
sonal computer.
Green/Yellow
wire
3
AUDIN - 7 bis rue de Tinqueux - 51100 Reims - France - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : [email protected]