7.2 Applied Operation
7 -19
7.2 Applied Operation
This section describes how to apply the basic operations using the Digital Operator to run and adjust
the motor. Read the basic operations described in
section 7.1
before proceeding to this section.
User constants for applied operation can be set in the auxiliary function mode. The following table
shows the user constants in the auxiliary function mode.
User Constant
Number
Function
Remarks
Fn000
Alarm traceback data display
Fn001
Rigidity setting during online autotuning
(See note.)
Fn002
JOG mode operation
Fn003
Zero-point search mode
Fn004
(Reserved constant)
Fn005
User constant settings initialization
(See note.)
Fn006
Alarm traceback data clear
(See note.)
Fn007
Writing inertia ratio data obtained from online autotuning to EEPROM
(See note.)
Fn008
Absolute encoder multi-turn reset and encoder alarm reset.
(See note.)
Fn009
Automatic tuning of analog (speed, torque) reference offset
(See note.)
Fn00A
Manual adjustment of speed reference offset
(See note.)
Fn00B
Manual adjustment of torque reference offset
(See note.)
Fn00C
Manual zero-adjustment of analog monitor output
(See note.)
Fn00D
Manual gain-adjustment of analog monitor output
(See note.)
Fn00E
Automatic offset-adjustment of motor current detection signal
(See note.)
Fn00F
Manual offset-adjustment of motor current detection signal
(See note.)
Fn010
Password setting (protects from user constant changes)
--
Fn011
Motor models display
--
Fn012
Software version display
--
Fn013
Multiturn limit value setting change when a Multiturn Limit Disagree-
ment alarm occurs
(See note.)
Fn014 *
Clear of option unit detection results
*
User constant Fn014 is supported by the new version of SGDH Servopacks only.
7