List of User Constants
B -6
B.2 Switches
The following list shows the switches and their factory settings.
User Constant
Digit
Place
Name
Setting
Contents
Factory
Setting
Pn000
Function Selection
0
Direction Selection
0
Sets CCW as forward direction.
0
Function Selection
Basic Switches
1
Sets CW as forward direction (reverse rotation
mode).
1
Control Method
Selection
0
Speed control (analog reference)
0
Selection
1
Position control (pulse train reference)
2
Torque control (analog reference)
3
Internal set speed control (contact reference)
4
Internal set speed control (contact refer-
ence)/Speed control (analog reference)
5
Internal set speed control (contact refer-
ence)/Position control (pulse train reference)
6
Internal set speed control (contact refer-
ence)/Torque control (analog reference)
7
Position control (pulse train reference)/
Speed control (analog reference)
8
Position control (pulse train reference)/
Torque control (analog reference)
9
Torque control (analog reference)/
Speed control (analog reference)
A
Speed control (analog reference)/
Zero clamp
B
Position control (pulse train reference)/
Position control (Inhibit)
2
Axis Address
0 to F
Sets Servopack axis address.
0
3
Reserved
---
0
B