5.2 Settings According to Host Controller
5 -17
J
J
Selecting a Reference Pulse Form
Use the following user constants to select the reference pulse form used.
®
Input PULS CN1-7
Reference Pulse Input
Position Control
®
Input /PULS CN1-8
Reference Pulse Input
Position Control
®
Input SIGN CN1-11
Reference Code Input
Position Control
®
Input /SIGN CN1-12
Reference Code Input
Position Control
The Servomotor only rotates at an angle proportional to the input pulse.
Pn200.0
Reference Pulse Form
Factory
Setting:
0
Position Control
Set reference pulse form input to the Servopack from the host controller.
Servopack
CN1-7
PULS
Position
reference
pulse
CN1-11
SIGN
Host
controller
Since the reference pulse form can be selected from among those listed below, set one according
to host controller specifications.
User
Constant
Pn200.0
Reference
Pulse Form
Input Pulse
Multiplier
Logic
Forward Rotation
Reference
Reverse Rotation Reference
0
Sign + pulse
train
--
Positive
logic
High
PULS
(CN1-7)
SIGN
(CN1-11)
Low
PULS
(CN1-7)
SIGN
(CN1-11)
1
CW pulse +
CCW pulse
--
Low
PULS
(CN1-7)
SIGN
(CN1-11)
Low
PULS
(CN1-7)
SIGN
(CN1-11)
2
Two-phase pulse
train with 90
°
´
1
90
°
PULS
(CN1-7)
90
°
PULS
(CN1-7)
3
train with 90
°
phase differential
´
2
PULS
(CN1-7)
SIGN
(CN1-11)
PULS
(CN1-7)
SIGN
(CN1-11)
4
phase differential
´
4
SIGN
(CN1-11)
SIGN
(CN1-11)
5
Sign + pulse
train
--
Negative
logic
Low
PULS
(CN1-7)
SIGN
(CN1-11)
High
PULS
(CN1-7)
SIGN
(CN1-11)
6
CW pulse +
CCW pulse
--
High
PULS
(CN1-7)
SIGN
(CN1-11)
High
PULS
(CN1-7)
SIGN
(CN1-11)
7
Two-phase pulse
train with 90
°
´
1
90
°
PULS
90
°
PULS
(CN1-7)
8
train with 90
°
phase differential
´
2
PULS
(CN1-7)
SIGN
(CN1-11)
PULS
(CN1-7)
SIGN
(CN1-11)
9
phase differential
´
4
SIGN
(CN1-11)
SIGN
(CN1-11)
5