B.1 User Constants
B -5
Category
Refer-
ence
Factory
Setting
Setting
Range
Unit
Name
User
Constant
No.
Sequence related
constants
Pn500
Positioning Completed Width
reference
units
0 to 250
7
5.5.3
constants
Pn501
Zero Clamp Level
r/min
0 to
10000
10
5.4.3
Pn502
Rotation Detection Level
r/min
1 to
10000
20
5.5.5
Pn503
Speed Coincidence Signal Output Width
r/min
0 to 100
10
5.5.4
Pn504
NEAR Signal Width
reference
units
1 to 250
7
5.5.8
Pn505
Overflow Level
256 refer-
ence units
1 to
32767
1024
6.2.1
Pn506
Brake Reference Servo OFF Delay Time
10 ms
0 to 50
0
5.4.4
Pn507
Brake Reference Output Speed Level
r/min
0 to
10000
100
5.4.4
Pn508
Timing for Brake Reference Output dur-
ing Motor Operation
10 ms
10 to 100 50
5.4.4
Pn509
Momentary Hold Time
ms
20 to
1000
20
5.5.9
Pn50A
Input Signal Selections 1 (See note 3.)
---
---
2100
5.3.3
Pn50B
Input Signal Selections 2 (See note 3.)
---
---
6543
5.3.3
Pn50C
Input Signal Selections 3 (See note 3.)
---
---
8888
5.3.3
Pn50D
Input Signal Selections 4 (See note 3.)
---
---
8888
5.3.3
Pn50E
Output Signal Selections 1 (See note 3.)
---
---
3211
5.3.4
Pn50F
Output Signal Selections 2 (See note 3.)
---
---
0000
5.3.4
Pn510
Output Signal Selections 3 (See note 3.)
---
---
0000
5.3.4
Pn511
Reserved constant (Do not change.)
---
---
8888
---
Pn512
Output Signal Reversal Settings (See note
3.)
---
---
0000
5.3.4
Other constants
Pn600
Regenerative Resistor Capacity
(See note 4.)
10 W
0 to ca-
pacity
*5
0
5.6.1
Pn601
Fixed constant (Do not change.)
---
0 to ca-
pacity
*5
0
---
* 1.
The multiturn limit must be changed only for special applications. Changing this limit inappropriate or uninten-
tionally can be dangerous.
* 2.
The setting of user constant Pn111 is valid only when user constant Pn110.1 is set to 0.
* 3.
After changing these user constants, turn OFF the main circuit and control power supplies and then turn them
ON again to enable the new settings. (except Pn 110.1 and Pn 110.2)
* 4.
Normally set to “0”. When using an External Regenerative Resistor, set the capacity (W) of the regenerative re-
sistor.
* 5.
The upper limit is the maximum output capacity (W) of the Servopack.
B