7.2 Applied Operation
7 -35
3.
Press the DATA/SHIFT Key for a minimum of one second to display the Servomotor model
and voltage code.
Servomotor Model
Voltage
Voltage
Servomotor Model
Code
Voltage
Code
Servomotor Model
00
100 VAC or 140 VDC
00
SGMAH
01
200 VAC or 280 VDC
01
SGMPH
02
400 VAC or 560VDC
02
SGMSH
03
SGMGH-
j
A (1500 r/min)
04
SGMGH-
j
B (1000 r/min)
05
SGMDH
06
SGMUH
4.
Press the MODE/SET Key to display the Servomotor capacity.
Capacity unit: Displayed value
´
10 [W]
This example shows 100 W.
5.
Press the MODE/SET Key, and the encoder type and resolution code will be displayed.
Encoder Type
Encoder Resolution
Encoder Type
Encoder Resolution
Code
Type
Code
Resolution
00
Incremental encoder
13
13 bits
01
Absolute encoder
16
16 bits
17
17 bits
20
Reserved
6.
Press the MODE/SET Key to display the Servopack’s modification index (Modification
No.)
This example shows modification index “Y10”.
(Indicated in decimal).
7.
Press the DATA/SHIFT Key to return to the auxiliary function mode display. Pressing the
DATA/SHIFT Key after the above display 3. to 5. will also return to the auxiliary function
mode display.
This completes the motor type checking procedure.
7