6.3 P02 Motor 1 Parameters
P02.00
Motor 1 Type
0: Asynchronous motor
0
●
P02.01
Rated Motor 1 Power
0.4kW~1000.0kW
Model
dependent
◎
P02.02
Rated Motor 1 Voltage
0V~1500V
Model
dependent
◎
P02.03
Rated Motor 1 Current
0.0A~2000.0A
Model
dependent
◎
P02.04
Rated Motor 1 Frequency
0.00Hz~P00.07
Model
dependent
◎
P02.05
Rated Motor 1 Rotation
Speed
0RPM~65535RPM
Model
dependent
◎
Caution: above parameter is setting motor 1 asynchronous motor, the user can input according to the
motor nameplate.
Note: The power of asynchronous motor should match with the inverter power class. Generally the
operating motor power is higher one class than inverter power, or motor power is smaller two
standard class than inverter power. Otherwise the control performance will be decreased.
P02.06
Motor 1 Stator
Resistance
0.000Ω~65.535Ω
Model
dependent
○
P02.07
Motor 1 Rotor Resistance
0.000Ω~65.535Ω
Model
dependent
○
P02.08
Motor 1 Rotor and Stator
Leakage Inductive
Reactance
0.0mH~6553.5mH
Model
dependent
○
P02.09
Motor 1 Rotor and Stator
Mutual Inductive
Reactance
0.0mH~6553.5mH
Model
dependent
○
P02.10
Motor 1 No-load Current
0.0A~P02.03(rated motor 1 current)
Model
dependent
○
Above parameter is the motor 1 mathematics mode detail parameter, don’t need user manually set.
When users change motor nameplate parameter or doing identification, above parameter will update
automatically. If user have knew motor model parameter, then no need doing parameter identification,
can be manual input. The mathematical model of single phase motor as below diagram showed:
Fig 6.3-1 Schematic diagram for mathematical model of single phase motor