Parameter Description
VD300 Series Inverter User Manual
- 108 -
Fig 6.6-6 Back and forth control mode
P05.01
DI1 Input Function
Selection
1
◎
P05.02
DI2 Input Function
Selection
2
◎
P05.03
DI3 Input Function
Selection
4
◎
P05.04
DI4 Input Function
Selection
6
◎
P05.05
DI5 Input Function
Selection
8
◎
P05.06
HDI1 Input Function
Selection (Can select HS
pulse input)
0
◎
P05.07
DI7 Input Function
Selection
(Extension card)
0
◎
P05.08
DI8 Input Function
Selection
(Extension card)
0
◎
P05.09
DI9 Input Function
Selection
(Extension card)
0~63, see table blow
0
◎
This parameter is used to set the functions of the multifunctional digital input terminals.
Set
Value
Function
Description
0
No function
The terminals not being used can be set “no function”, to avoid
wrong operation;
1
Forward running
2
Reverse running
Via external terminals to control inverter forward reverse run;
3
Three-line run control
Via this terminal to confirm the inverter run mode is 3line run or
alternative control mode. Refer to function code P05.00 (“terminal
control run mode”) description;