VD300 Series Inverter User Manual
Function Parameter Table
- 71 -
P11.16
Simple PLC
0: Stop after the inverter runs one cycle
1: Keep final value after the inverter runs
one cycle
2: Cycle running
0
○
P11.17
PLC Restart Mode
Selection
0: Restart from reference 1
1: Restart from the stage of interruption
time frequency
0
○
P11.18
Simple PLC
Retentive
0: Retentive at power failure
1: Non- retentive at power failure
0
○
P11.19
MS Time Unit Setup
0: S (second)
1: Min (minute)
0
◎
P11.20
Time of Reference 0
0.0s (h)~6000.0s (h)
0.0s
○
P11.21
Acceleration /
Deceleration Time
Selection of
Reference 0
0~3
0
○
P11.22
Time of Reference 1
0.0s (h)~6000.0s (h)
0.0s
○
P11.23
Acceleration /
Deceleration Time
Selection of
Reference 1
0~3
0
○
P11.24
Time of Reference 2
0.0s (h)~6000.0s (h)
0.0s
○
P11.25
Acceleration /
Deceleration Time
Selection of
Reference 2
0~3
0
○
P11.26
Time of Reference 3
0.0s (h)~6000.0s (h)
0.0s
○
P11.27
Acceleration /
Deceleration Time
Selection of
Reference 3
0~3
0
○
P11.28
Time of Reference 4
0.0s (h)~6000.0s (h)
0.0s
○
P11.29
Acceleration /
Deceleration Time
Selection of
Reference 4
0~3
0
○
P11.30
Time of Reference 5
0.0s (h)~6000.0s (h)
0.0s
○
P11.31
Acceleration /
Deceleration Time
Selection of
Reference 5
0~3
0
○
P11.32
Time of Reference 6
0.0s (h)~6000.0s (h)
0.0s
○