P03.27
Vector Control Weak
Magnetic Proportion Gain
0~4000
1200
○
In vector control mode, when motor RPM is higher than rate RPM, this parameter is used to adjust
current response speed.
P03.28
Low Frequency Torque
Compensation
Coefficient
0.0%~50.0%
0.0%
○
P03.29
High Frequency Torque
Compensation
Coefficient
0.0%~50.0%
0.0%
○
P03.30
Low Frequency Torque
Compensation Cutoff
Frequency
0.00Hz~50.00Hz
5.00Hz
○
P03.31
High Frequency Torque
Compensation Cutoff
Frequency
0.00Hz~100.00Hz
50.00Hz
○
Above 4 parameter are under torque control mode, separately used to set low frequency
compensation factor and low frequency compensation cutoff frequency, high frequency compensation
factor and high frequency compensation cutoff frequency. When inverter output frequency lower than
P03.30, torque compensation is P03.28 setting coefficient; when inverter output frequency is higher
than P03.31, torque compensation is P03.29 setting coefficient; when inverter output frequency is
between P0.30~P03.31, torque compensation is P03.28 and P03.29 linear interpolation coefficient.
P03.32
Acceleration/Deceleratio
n Torque Compensation
Coefficient
0.000~10.000
0.000
○
P03.33
Acceleration/Deceleratio
n Torque Compensation
Upper Limit
0.0%~50.0%
5.0%
○
P03.34
Acceleration/Deceleratio
n Torque Compensation
Frequency Lower Limit
0.00Hz~50.00Hz
10.00Hz
○
Above 3 parameters are under vector control mode, when motor is under Acceleration/down status,
its torque compensation coefficient, compensation upper limit and compensation lower limit frequency.
So properly set the group parameter is helpful for stop/start or Acceleration/down invariable tension.
P03.35
Torque Control Stator
Resistance
Compensation Selection
0: Disabled
1: Enabled
0
○