VD300 Series Inverter User Manual
Parameter Description
- 141 -
6.11 P10 Keyboard and Display
P10.00
STOP/RESET Key Stop
Function
0: Only enabled to panel control
1: Enabled to panel and terminal control
at the same time
2: Enabled to panel and communication
at the same time
3: Enabled to all control mode
0
○
This parameter is used to set STOP/RESET key function selection.
RESET function is always enabled, no matter what value is set for the parameter.
P10.01
REV/JOG Key Function
0: No function
1: Jog running
2: FWD/REV switchover
3: Coast to stop
4: Clear up/down & ^/v key setup
frequency
5: Shift key switchover display state
6: To achieve run command given way
according to switchover sequence
7: Quick debugging mode (according to
factory parameter debugging)
8: Modify rapidly set frequency
1
◎
This parameter is used to set JOG/REV button function selection
P10.02
JOG/REV Key Run
Command Channel
Switchover Sequential
Selection
0: Keyboard control ←→ terminal
control
1: Keyboard control ←→
communication control
2: Terminal control ←→ communication
control
3: Keyboard control → terminals
Control → communication control
3
○
When P10.01 set as 6, this parameter is used to set JOG/REV button function selection.
P10.03
Display Running Lower
Bit
0x0000~0xffff
BIT0: Running frequency (Hz light on)
BIT1: Sett frequency(Hz flash)
BIT2: Bus voltage(V light on)
BIT3: Output voltage(V light on)
BIT4: Output current(A light on)
BIT5: Run speed(RPM on)
BIT6: Output power(% light on)
BIT7: Output torque (% light on)
BIT8: PID setting value (% flash)
BIT9: PID Feedback value(% light on)
BIT10: State of input terminals
0x003F
○