DC braking before start process as below diagram:
Fig 6.2-2 Schematic diagram for the braking current before starting
P01.05
Stop Mode
Selection
0: Decelerate to stop
1: Coast to stop
0
○
Deceleration to stop: Deceleration to stop is motor relying on inverter braking, under set Deceleration
time reducing to zero. Different application can adopt different stop mode.
Coast to stop: Coast to stop is inverter cut off motor current after receiving stop command, motor
relying its inertia reduce speed to zero.
After coast to stop, the motor is still in the high speed rotation, to prevent equipment damage or
personal injury caused by!
P01.06
Initial Frequency of
Stop Braking
0.00Hz~P00.07 (max output frequency)
0.00Hz
○
P01.07
Waiting Time of
Stop Braking
0.000s: Auto delay
0.001s~60.000s
0.00s
○
P01.08
Stop DC Braking
Current
0.0%~100.0%
0.0%
○
P01.09
Stop DC Braking
Time
0.00s~60.00s
0.00s
○
During deceleration process, if frequency reducing to P01.06, waiting P01.07 setup time, starting
input DC current to motor, acceleration braking. The input current value is set by P01.08, 100.0% is
equal to rate inverter current, input DC current time is set by P01.09, if braking time is 0, then no need
this process. Such as below diagram: