Parameter Description
VD300 Series Inverter User Manual
- 148 -
The parameter is used for setting PLC cycle run mode.
Stop after completion of one cycle: the inverter will automatically stop upon completion of one single
cycle, and will not restart until another run command is given to start.
Keep final value upon completion of one-time run: the inverter will automatically keep the run
frequency and direction of latest stage after completion of one single cycle.
Cycle operation: The inverter will automatically start next one cycle upon completion of one cycle, and
will not stop until stop command is given.
P11.17
PLC Restart Mode
Selection
0: Restart from reference 1
1: Restart from the stage of interruption
time frequency
0
○
This parameter is used to set simple PLC restart after stopped, whether to choose to restart run or run
from interrupted stage.
P11.18
Simple PLC Retentive
0: Retentive at power failure
1: Non- retentive at power failure
0
○
This parameter is used to set memory selection when simple PLC stopped or power loss.
P11.19
MS Time Unit Setup
0: S (second)
1: Min (minute)
0
◎
This parameter is used to set the run time unit selection of simple PLC.
P11.20
Time of Reference 0
0.0s (h)~6000.0s (h)
0.0s
○
P11.21
Acceleration/Deceleration
Time of Reference 0
0~3
0
○
P11.22
Time of Reference 1
0.0s (h)~6000.0s (h)
0.0s
○
P11.23
Acceleration /
Deceleration Time
Selection of Reference 1
0~3
0
○
P11.24
Time of Reference 2
0.0s (h)~6000.0s (h)
0.0s
○
P11.25
Acceleration /
Deceleration Time
Selection of Reference 2
0~3
0
○
P11.26
Time of Reference 3
0.0s (h)~6000.0s (h)
0.0s
○
P11.27
Acceleration /
Deceleration Time
Selection of Reference 3
0~3
0
○
P11.28
Time of Reference 4
0.0s (h)~6000.0s (h)
0.0s
○
P11.29
Acceleration /
Deceleration Time
Selection of Reference 4
0~3
0
○
P11.30
Time of Reference 5
0.0s (h)~6000.0s (h)
0.0s
○
P11.31
Acceleration /
Deceleration Time
0~3
0
○