VD300 Series Inverter User Manual
Parameter Description
- 159 -
This parameter is used to display the fault code when user to view the error record. If displaying is 0,
that indicates no fault record.
P14.02
Run Frequency upon
Fault
0.00hz~650.00Hz
0.00Hz
●
P14.03
Current Upon Fault
0.0A~2000.0A
0.0A
●
P14.04
Output Voltage upon
Fault
0v~2000V
0V
●
P14.05
Bus Voltage upon Fault
0.0v~2000.0V
0.0V
●
P14.06
Input Terminal State
upon Fault
0x000~0x1FF
0x000
●
P14.07
Output Terminal State
upon Fault
0x00~0x1F
0x00
●
P14.08
Inverter Temperate upon
Fault
-20.0°c~120.0°C
0.0°C
●
P14.09
Run Time upon Fault
0min~65535min
0min
●
P14.10
Power-On Time upon
Fault
0min~65535min
0min
●
P14.11
Accumulative Running
Time upon Fault
0h~65535h
0h
●
P14.12
Accumulative Power-On
Time upon Fault
0h~65535h
0h
●