Parameter Description
VD300 Series Inverter User Manual
- 146 -
6.12 P11 MS Speed Function and Simple PLC Function
MS frequency given as frequency mode is applied in MS speed run mode and simple PLC run mode.
When frequency source command A or B is selected as MS speed command, inverter run frequency
is MS speed mode.
P11.00
Multi-reference 0
-100.0%~100.0%
0.0%
○
P11.01
Multi-reference 1
-100.0%~100.0%
0.0%
○
P11.02
Multi-reference 2
-100.0%~100.0%
0.0%
○
P11.03
Multi-reference 3
-100.0%~100.0%
0.0%
○
P11.04
Multi-reference 4
-100.0%~100.0%
0.0%
○
P11.05
Multi-reference 5
-100.0%~100.0%
0.0%
○
P11.06
Multi-reference 6
-100.0%~100.0%
0.0%
○
P11.07
Multi-reference 7
-100.0%~100.0%
0.0%
○
P11.08
Multi-reference 8
-100.0%~100.0%
0.0%
○
P11.09
Multi-reference 9
-100.0%~100.0%
0.0%
○
P11.10
Multi-reference 10
-100.0%~100.0%
0.0%
○
P11.11
Multi-reference 11
-100.0%~100.0%
0.0%
○
P11.12
Multi-reference 12
-100.0%~100.0%
0.0%
○
P11.13
Multi-reference 13
-100.0%~100.0%
0.0%
○
P11.14
Multi-reference 14
-100.0%~100.0%
0.0%
○
P11.15
Multi-reference 15
-100.0%~100.0%
0.0%
○
MS speed command 100.0% is corresponding max output frequency P00.07, minus sign stand for
reverse run. The inverter can set 16stage speed, selected by combined code via external terminal
DIin1, DIin2, DIin3, DIin4, separately corresponding to MS speed 0 to MS speed 15.
Содержание VD300 Series
Страница 2: ......