background image

 
 
 
S

UPPORT

 

Models  supported  include  tSH-722,  tSH-732,  tSH-725, 

tSH-735, tSH-724, tSH-734, tSH-722i, tSH-732i, tSH-725i, 

tSH-735i, tSH-724i and tSH-734i.

 

 
W

ARRANTY

 

All  products  manufactured  by  ICP  DAS  are  warranted 

against defective materials for a period of one year from 

the date of delivery to the original purchaser.

 

 
 

W

ARNING

 

ICP DAS assumes no liability for damages consequent to 

the  use  of  this  product.  ICP  DAS  reserves  the  right  to 

change  this  manual  at  any  time  without  notice.  The 

information  furnished  by  ICP  DAS  is  believed  to  be 

accurate  and  reliable.  However,  no  responsibility  is 

assumed  by  ICP  DAS  for  its  use,  nor  for  any 

infringements of patents or other rights of third parties 

resulting from its use.

 

 
 

C

OPYRIGHT

 

Copyright ©  2017 by ICP DAS. All rights are reserved.

 

 
 

T

RADEMARKS

 

Names  are  used  for  identification  purposes  only  and 

may  be  registered  trademarks  of  their  respective 

companies.

 

 
 

C

ONTACT 

U

S

 

If you have any questions, please feel free to contact us 

via email at: 

[email protected] 

or

 [email protected]

   

 

 

 

 

 

 

 

 

 

 

 

Version: 1.2/Updated: Jun. 2017 

 

tSH-700 Series 

Firmware Update via Ethernet 

ICP DAS CO., LTD. 

Website: http://www.icpdas.com 

Ch. 2. Firmware Update Procedure 

Ch. 1. Setting up the tSH-700 

Ch. 3. Troubleshooting 

Ch. 4. Additional Information 

Ch. 0. How to identify your tSH-700 type 

Содержание tSH-700 Series

Страница 1: ...reliable However no responsibility is assumed by ICP DAS for its use nor for any infringements of patents or other rights of third parties resulting from its use COPYRIGHT Copyright 2017 by ICP DAS Al...

Страница 2: ...to update the firmware If the module name shows RevB please download tSH700_RevBxxx_xxxxxx zip firmware file to update on the contrary the module name is not RevB please download tSH700fw_vxxx_xxxxxx...

Страница 3: ...directly to the Internet as this may cause the update process to fail Refer to Chapter 3 Connecting the Power and Host PC in the tSH 700 Quick Start Guide for more detailed information Download the Q...

Страница 4: ...pdate Refer to Section 2 1 Local Firmware Update for more details The Remote Firmware Update method allows the user to initialize the module via a web interface without needing to adjust the hardware...

Страница 5: ...ile Supports tSH 700 module tSH700 dat tSH 700 Series tSH700_RevB dat tSH 700RevB Series Step 5 Assign a valid IP Address can be different with the current IP and the factory default MAC Address for t...

Страница 6: ...nit Mode to initiate the update Step 10 Confirm that the two MAC addresses factory default listed in the Command Prompt window Waiting request from MAC x x x x and BOOTPREQ from MAC x x x x are the sa...

Страница 7: ...erate the module in Run Mode Step 13 In the eSearch Utility search for the tSH 700 module again to verify that it is functioning correctly Note that the network settings for the module may need to be...

Страница 8: ...Update via Ethernet Ver 1 2 Jun 2017 Page 7 Step 16 Log in to the web configuration pages for the tSH 700 use the default password admin Step 17 Verify that the version and date details for the firmwa...

Страница 9: ...ollow the procedure described below to update firmware of the tSH 700 on the remote PC Step 1 In the eSearch Utility click the Search Servers button to search for any tSH 700 modules connected to the...

Страница 10: ...orts tSH 700 module tSH700 dat tSH 700 Series tSH700_RevB dat tSH 700RevB Series Step 5 Assign a valid IP Address can be different with the current IP and the factory default MAC Address for the tSH 7...

Страница 11: ...ndow will be displayed to indicate the progress of the update Step 8 Open a web browser such as Internet Explorer or Firefox and enter the URL for the tSH 700 in the address bar of the browser and log...

Страница 12: ...m MAC x x x x and BOOTPREQ from MAC x x x x are the same as indicated in the image below If these addresses do not match the update cannot proceed Refer to note4 Page 19 below for more details Step 12...

Страница 13: ...need to be reconfigured after updating the firmware Refer to Step 3 in Chapter 1 above for more details Step 14 Click the name of the tSH 700 module to highlight it Step 15 Click the Web button and t...

Страница 14: ...ate the firmware for the module using the following procedure Step 1 In the eSearch Utility select the BOOTP item from the Server menu A check mark should be displayed next to the item after it has be...

Страница 15: ...menu Step 5 Refer to Steps 4 to 17 in Chapter 2 Firmware Update Procedure for details of how to complete the update process Note the module will response with no IP address in the BOOTP mode User has...

Страница 16: ...t PC IP address is 10 0 8 31 refer to the following two methods to update firmware Method 1 Using Dynamic Host Configuration Protocol DHCP to automatically assigns an IP address to tSH 700 module Foll...

Страница 17: ...Jun 2017 Page 16 Step 4 Wait 2 seconds and then click the Search Servers button again to ensure the tSH 700 is working well with new configuration Step 5 Refer to Chapter 2 Firmware Update Procedure...

Страница 18: ...the eSearch Utility to search for any tSH 700 modules to the network Step 2 Double click the name of tSH 700 to open the Configure Server UDP dialog box Step 3 Select the 0 OFF option from the DHCP dr...

Страница 19: ...Jun 2017 Page 18 Step 5 Wait 2 seconds and then click the Search Servers button again to ensure the tSH 700 is working well with new configuration Step 6 Refer to Chapter 2 Firmware Update Procedure...

Страница 20: ...re that prevents any modifications from being made to the firmware stored in the flash memory so before attempting to update the firmware the Init Switch should be set to the Init position and then th...

Страница 21: ...not begin if a user defined MAC address is assigned in the firmware update window since the addresses do not match If this situation occurs repeat the update procedure and manually enter the factory d...

Отзывы: