E6582175
D-12
4
Save user setting parameters (
typ
=
7
)
Setting
typ
to
7
saves the current settings of all parameters.
Load user setting parameters (
typ
=
8
)
Setting
typ
to
8
loads parameter settings to (calls up) those saved by setting
typ
to
7
.
* By setting
typ
to
7
or
8
, you can use parameters as your own default parameters.
Cumulative fan operation time record clear (
typ
=
9
)
Setting
typ
to
9
resets the cumulative operation time to the initial value (zero).
Set this parameter when replacing the cooling fan, and so on
Number of starting clear (
typ
=
12
)
Setting
typ
to
12
resets the number of starting to the initial value (zero).
Default setting 2 (
typ
=
13
)
Set
typ
to
13
to return all parameters to their default settings.
When
13
is set,
init
is displayed for a short time after the settings are configured, and then
disappears. Then setup menu
set
is displayed. After reviewing the setup menu items, make a setup
menu selection. In this case, all parameters are returned to their defaults, and the trip history data is cleared.
(Refer to section 3.1)