E6582175
K-13
11
Title
Communication
No.
Function
Unit
Minimum
setting unit
Panel/Commun
ication
Adjustment range
Default
setting
User
setting
Reference
0331
Light-load high-
speed operation
switching lower
limit frequency
Hz
0.1/0.01
5.0-
ul
40.0
6.21
0329
Light-load high-
speed learning
function
-
-
0:No learning
1:Forward run learning
2:Reverse run learning
0
0330
Automatic light-load
high-speed
operation frequency
Hz
0.1/0.01
30.0-
ul
*1
0332
Light-load high-
speed operation
load waiting time
s
0.1/0.1
0.0-10.0
0.5
0333
Light-load high-
speed operation
load detection time
s
0.1/0.1
0.0-10.0
1.0
0334
Light-load high-
speed operation
heavy load
detection time
s
0.1/0.1
0.0-10.0
0.5
0335
Switching load
torque during
power running
%
1/0.01
-250- +250
50
0336
Heavy-load torque
during power running
%
1/0.01
-250- +250
100
0337
Heavy-load torque
during constant
power running
%
1/0.01
-250- +250
50
0338
Switching load
torque during
regenerative braking
%
1/0.01
-250- +250
50
0339
Factory specific
coefficient 3D
-
-
-
-
* 3
0340
Creeping time 1
s
0.01/0.01
0.00-10.00
0.00
6.22.1
0341
Braking mode
selection
-
-
0: Disabled
1: Forward winding up
2: Reverse winding up
3: Horizontal operation
0
0342
Load portion
torque input
selection
-
-
0: Disabled
1: Terminal VIA
2: Terminal VIB
3: Terminal VIC
4:
f343
4
0343
Hoisting torque bias
input (valid only
when
=
)
%
1/0.01
-250- +250
100
0344
Lowering torque
bias multiplier
%
1/0.01
0-100
100
0345
Brake release time
s
0.01/0.01
0.00-10.00
0.05
0346
Creeping frequency
Hz
0.1/0.01
f240
-20.0
3.0
0347
Creeping time 2
s
0.01/0.01
0.00-10.00
0.10
0348
Braking time
learning function
-
1/1
0:Disabled
1: Learning (0 after adjustment)
0
*1: Default setting values vary depending on the setup menu setting. Refer to section 11.5.
*3: Factory specific coefficient parameters are manufacturer setting parameters. Do not change the value of these parameters.
Содержание TOSVERT VF-S15 series
Страница 394: ......