E6582175
F-146
6
6.38.4 Open network option
c700
to
c789
,
c800
to
c830
: CANopen communication
parameters
c001
to
c111
,
c160
to
c164
: Communication option common
c885
to
c896
,
c900
to
c999
parameters
c120
to
c148
: CC-Link option parameters
c150
to
c159
: PROFIBUS DP option parameters
c200
to
c203
: DeviceNet option parameters
c400
to
c421
,
c850
to
c880
: EtherCAT option parameters
c500
to
c536
: EtherNet common parameters
c554
to
c556
: EtherNet/IP option parameters
c600
to
c604
: Modbus TCP option parameters
● CANopen option (Type: CAN001Z, CAN002Z, CAN003Z)
CC- Link option
(Type: CCL003Z)
PROFIBUS DP option
(Type: PDP003Z)
DeviceNet option
(Type: DEV003Z)
EtherNet / IP-Modbus TCP option (Type: IPE002Z)
EtherCAT option
(Type: IPE003Z)
Refer to each Instruction Manual of option for details.
6.39 Permanent magnet motors
f910
: Step-out detection current level
f911
: Step-out detection time
f912
: q-axis inductance
f913
: d-axis inductance
f915
: Factory specific coefficient 9L
Function
If the permanent magnet motor (PM motor) steps out and if the exciting current increases (it increases
in such a case) and remains above the value set with
f910
for the period of time set with
f911
,
the inverter will judge the motor to be stepping out and trip it. At that time, the trip message
"
sout
" is displayed.