E6582175
K-31
11
Title
Communication
No.
Function
Unit
Minimum
setting unit
Panel/Commun
ication
Adjustment range
Default
setting
User
setting
Reference
0829
Selection of
communication
protocol
-
-
0: Toshiba inverter protocol
1: Modbus RTU protocol
0
6.38.1
0856
Number of motor
poles for
communication
-
-
1: 2 poles
2: 4 poles
3: 6 poles
4: 8 poles
5: 10 poles
6: 12 poles
7: 14 poles
8: 16 poles
2
0870
Block write data 1
-
-
0: No selection
1: Communication command 1
2: Communication command 2
3: Frequency command value
4: Output data on the terminal block
5: FM analog output
6: Motor speed command
0
0871
Block write data 2
-
-
0
0875
Block read data 1
-
-
0: No selection
1: Status information 1
2: Output frequency
3: Output current
4: Output voltage
5: Alarm information
6: PID feedback value
7: Input terminal monitor
8: Output terminal monitor
9: Terminal VIA monitor
10: Terminal VIB monitor
11: Terminal VIC monitor
12: Input voltage (DC detection)
13: Motor speed
14: Torque
0
0876
Block read data 2
-
-
0
0877
Block read data 3
-
-
0
0878
Block read data 4
-
-
0
0879
Block read data 5
-
-
0
0880
Free notes
-
1/1
0-65530 (65535)
0
6.38.3
0896
RKP002Z option
parameter 1
-
-
-
-
*15
0897
Factory specific
coefficient 8B
-
-
-
-
*3
0898
Factory specific
coefficient 8A
-
-
-
-
0899
Communication
function reset
-
-
0: -
1: Reset (after execution: 0)
0
6.38.1
*1: Default setting values vary depending on the setup menu setting. Refer to section 11.5.
*3: Factory specific coefficient parameters are manufacturer setting parameters. Do not change the value of these parameters.
*15: RKP002Z option parameter is manufacturer setting parameter. Do not change the value of the parameter.