E6582175
F-30
6
(2) [
f105
=
1
(Stop)]: If an F command and an R command are entered simultaneously,
the motor will deceleration stop.
Forward run
Reverse run
Forward run command
Reverse run command
ON
OFF
ON
OFF
Output frequency [Hz]
Setting frequency
Time[s]
0
6.6.2
Changing the voltage range of VIB terminal
f107
: Analog input terminal selection (VIB)
Function
This parameter allows you to choose the voltage signal input for the VIB terminal.
[Parameter setting]
Title
Function
Adjustment range
Default setting
f107
Analog input terminal
selection (VIB)
0: 0-+10V
1: -10-+10V
0
●
f107
=
0
: Input 0 to +10Vdc to VIB-CC terminals.
Resolution is maximum 1/1000 between 0 to +10Vdc.
●
f107
=
1
: Input -10 to +10Vdc to VIB-CC terminals.
Resolution is maximum 1/2000 between -10 to +10Vdc.
Содержание TOSVERT VF-S15 series