E6582175
K-23
11
Output parameters
Title
Communication
No.
Function
Unit
Minimum
setting unit
Panel/Commun
ication
Adjustment range
Default
setting
User
setting
Reference
0667
Integral input
power pulse
output unit
-
-
0: 0.1kWh
1: 1kWh
2: 10kWh
3: 100kWh
1
6.33.1
0668
Integral input
power pulse
output width
s
0.1/0.1
0.1-1.0
0.1
0669
Logic output/pulse
train output
selection (OUT)
-
-
0: Logic output
1: Pulse train output
0
6.33.2
0676
Pulse train output
function selection
(OUT)
-
-
0: Output frequency
1: Output current
2: Frequency command value
3: Input voltage (DC detection)
4: Output voltage (command value)
5: Input power
6: Output power
7: Torque
8: -
9: Motor cumulative load factor
10: Inverter cumulative load factor
11: PBR (Braking resistor) cumulative
load factor
12: Stator frequency
13: VIA input value
14: VIB input value
15: Fixed output 1
(output current 100% equivalent)
16: Fixed output 2
(output current 50% equivalent)
17: Fixed output 3
(Other than the output current)
18: Communication data
19: -
20: VIC input value
21, 22: -
23: PID feedback value
24-52: -
53: PBR (Braking resistor) load factor
0
0677
Maximum numbers
of pulse train
output
kpps
0.01/0.01
0.50-2.00
0.80
0678
Pulse train output
filter
ms
1/1
2-1000
64
0679
Pulse train input
filter
ms
1/1
2-1000
2
6.10.5
0681
Analog output
signal selection
-
-
0: Meter option (0 to 1 mA)
1: Current (0 to 20 mA) output
2: Voltage (0 to 10 V) output
0
5.1
6.33.3
0684
Analog output
filter
ms
1/1
2-1000
2
0691
Inclination
characteristic of
analog output
-
-
0: Negative inclination (downward
slope)
1: Positive inclination (upward slope)
1
0692
Analog output bias
%
0.1/0.1
-1.0
-
+100.0
0.0
0693
Factory specific
coefficient 6E
-
-
-
-
* 3
0699
Factory specific
coefficient 6F
-
-
-
-
*3: Factory specific coefficient parameters are manufacturer setting parameters. Do not change the value of these parameters.