E6582175
D-17
4
Shortcut key function (
f750
=
1
)
This function allows you to register, in a shortcut list, parameters whose settings need to be changed frequently so
that you can read them out easily in a single operation.
The shortcut is usable in the frequency monitor mode only.
[Operation]
Set
f750
to
1
, read out the setting of the parameter you want to register, and press and hold down the EASY
key for 2 seconds or more. The registration of the parameter in a shortcut list has been completed.
To read out the parameter, just press the EASY key.
Local / Remote switching (
f750
=
2
)
This function allows you to easily switch between panel operation and external operation.
To switch between control device, set
f750
to
2
, and then select the desired control device, using the EASY key.
If bumpless operation selection
f295
is set to
1
(Enabled), it can be switched during operation.
Local means panel operation.
Remote means the operation that is selected by command mode selection:
cmod
and frequency setting mode
selection:
fmod
(
f207
).
In the Local mode, the EASY key lamp lights.
Note) Please note that if set the parameter
f750
to
0
in local mode, the panel operation state holds and it
becomes different from setting of
cmod
.
Peak hold function (
f750
=
3
)
This function allows you to set peak hold and minimum hold triggers for parameters
f709
, using the EASY key.
The measurement of the minimum and maximum values set for
f709
starts the instant when you press the
EASY key after setting
f750
to
3
.
The peak hold and minimum hold values are displayed in absolute values.
External operation
(Remote)
Panel operation
(Local)
Move to Panel operation (Local).
If the bumpless function is selected,
remote operation status is directly
moved.
Move to external operation (Remote).
(Even if the bumpless function is selected,
operation status is not moved.)
EASY