E6582175
H-8
8
(Continued)
Item displayed
Panel
operated
LED
display
Communic
ation No.
Description
Communication
Status
sl }}
FD57
The status of signal transmission and reception of
communication are displayed in bits.
receiving or transmitting :
not receiving or not transmitting:
Parts replacement
alarm information
m
}}}}i
FE79
The ON/OFF status of each of the cooling fan,
circuit board capacitor, main circuit capacitor of
parts replacement alarm, cumulative operation
time
or number of starting are displayed in bits.
ON:
OFF:
Cumulative
operation time
FE14
The cumulative operation time is displayed.
(0.10=10 hours, 1.00=100 hours)
Number of starting
FD32
Number of starting (10000 times)
Default display
mode
The cause of the trip is displayed.
Note 1: The characters to the left disappear at 100 Hz or more. (Ex: 120 Hz is
)
Note 2: You can switch between % and A (ampere)/V (volt), using the parameter
(current/voltage unit
selection).
Note 3: The input (DC) voltage displayed is 1/
2
times as large as the rectified d.c. input voltage.
Note 4: < VIA bar >
=
3
,
4
(Contact input): activated ON/OFF depend on VIA terminal input.
=
0
to
2
(Analog input): always OFF.
< VIB bar >
=
1
to
4
(Contact input): activated ON/OFF depend on VIB terminal input.
=
0
(Analog input): always OFF.
< S2 bar >
46
=
0
(Contact input): activated ON/OFF depend on S2 terminal input.
46
=
1
(Pulse train input): always OFF.
< S3 bar >
47
=
0
(Contact input): activated ON/OFF depend on S3 terminal input.
47
=
1
(PTC input): always OFF.
Note 5: < OUT bar >
=
0
(Logic output): activated ON/OFF depend on OUT terminal output.
=
1
(Pulse train output): always OFF.
Note 9
Note 8
m
}}}}
i
Cooling fan
Cumulative
operation time
Control circuit board
capacitor
Main circuit
capacitor
Number of starting
MODE
}}
TX: signal
transmitting
RX: signal receiving
sl